DiskStation> smartctl -a -d marvell /dev/hda smartctl version 5.38 [armle-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: FUJITSU MJA2500BH G2 Serial Number: ************ Firmware Version: 00000018 User Capacity: 500,107,862,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: ATA-8-ACS revision 3f Local Time is: Wed Apr 21 21:20:46 2010 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (1574) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 223) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 100 100 046 Pre-fail Always - 124773 2 Throughput_Performance 0x0005 100 100 030 Pre-fail Offline - 69861376 3 Spin_Up_Time 0x0003 100 100 025 Pre-fail Always - 1 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 3 5 Reallocated_Sector_Ct 0x0033 100 100 024 Pre-fail Always - 9019431321600 7 Seek_Error_Rate 0x000f 100 100 047 Pre-fail Always - 4058 8 Seek_Time_Performance 0x0005 100 100 019 Pre-fail Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 150 10 Spin_Retry_Count 0x0013 100 100 020 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 3 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 1 193 Load_Cycle_Count 0x0032 100 100 000 Old_age Always - 15 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 31 (Lifetime Min/Max 24/38) 195 Hardware_ECC_Recovered 0x001a 100 100 000 Old_age Always - 9761 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 826015744 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 253 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x000f 100 100 060 Pre-fail Always - 23273 203 Run_Out_Cancel 0x0002 100 100 000 Old_age Always - 2628530143811 240 Head_Flying_Hours 0x003e 200 200 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 0 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. DiskStation> smartctl -a -d marvell /dev/hdb smartctl version 5.38 [armle-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: Hitachi HTS545050B9A300 Serial Number: ******************** Firmware Version: PB4OC64G User Capacity: 500,107,862,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Not recognized. Minor revision code: 0x28 Local Time is: Wed Apr 21 21:20:54 2010 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 645) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 158) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000b 099 099 062 Pre-fail Always - 65537 2 Throughput_Performance 0x0005 100 100 040 Pre-fail Offline - 0 3 Spin_Up_Time 0x0007 132 132 033 Pre-fail Always - 2 4 Start_Stop_Count 0x0012 100 100 000 Old_age Always - 20 5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always - 0 7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always - 0 8 Seek_Time_Performance 0x0005 100 100 040 Pre-fail Offline - 0 9 Power_On_Hours 0x0012 092 092 000 Old_age Always - 3856 10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 20 191 G-Sense_Error_Rate 0x000a 100 100 000 Old_age Always - 0 192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always - 9 193 Load_Cycle_Count 0x0012 010 010 000 Old_age Always - 904952 194 Temperature_Celsius 0x0002 196 196 000 Old_age Always - 28 (Lifetime Min/Max 21/38) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 1 197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x000a 200 200 000 Old_age Always - 0 223 Load_Retry_Count 0x000a 100 100 000 Old_age Always - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 1554 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. DiskStation> smartctl -a -d marvell /dev/hdc smartctl version 5.38 [armle-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: WDC WD5000BEVT-00A0RT0 Serial Number: *************** Firmware Version: 01.01A01 User Capacity: 500,107,862,016 bytes Device is: Not in smartctl database [for details use: -P showall] ATA Version is: 8 ATA Standard is: Exact ATA specification draft version not indicated Local Time is: Wed Apr 21 21:20:57 2010 CEST SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (13200) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 154) minutes. Conveyance self-test routine recommended polling time: ( 5) minutes. SCT capabilities: (0x7037) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 200 200 051 Pre-fail Always - 0 3 Spin_Up_Time 0x0027 225 223 021 Pre-fail Always - 1716 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 20 5 Reallocated_Sector_Ct 0x0033 200 200 140 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 200 200 000 Old_age Always - 0 9 Power_On_Hours 0x0032 098 098 000 Old_age Always - 1630 10 Spin_Retry_Count 0x0033 100 253 051 Pre-fail Always - 0 11 Calibration_Retry_Count 0x0032 100 253 000 Old_age Always - 0 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 19 192 Power-Off_Retract_Count 0x0032 200 200 000 Old_age Always - 18 193 Load_Cycle_Count 0x0032 110 110 000 Old_age Always - 270539 194 Temperature_Celsius 0x0022 117 106 000 Old_age Always - 30 196 Reallocated_Event_Count 0x0032 200 200 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 200 200 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 253 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x0009 100 253 051 Pre-fail Offline - 0 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 866 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay. DiskStation> smartctl -a -d marvell /dev/hdd smartctl version 5.38 [armle-unknown-linux-gnu] Copyright (C) 2002-8 Bruce Allen Home page is http://smartmontools.sourceforge.net/ === START OF INFORMATION SECTION === Device Model: SAMSUNG HM500JI Serial Number: ************** Firmware Version: 2AC101C4 User Capacity: 500,107,862,016 bytes Device is: In smartctl database [for details use: -P show] ATA Version is: 8 ATA Standard is: Not recognized. Minor revision code: 0x28 Local Time is: Wed Apr 21 21:20:59 2010 CEST ==> WARNING: May need -F samsung or -F samsung2 enabled; see manual for details. SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: (8520) seconds. Offline data collection capabilities: (0x5b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. No Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 142) minutes. SCT capabilities: (0x003f) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 100 051 Pre-fail Always - 0 2 Throughput_Performance 0x0026 252 252 000 Old_age Always - 0 3 Spin_Up_Time 0x0023 089 089 025 Pre-fail Always - 3430 4 Start_Stop_Count 0x0032 100 100 000 Old_age Always - 16 5 Reallocated_Sector_Ct 0x0033 252 252 010 Pre-fail Always - 0 7 Seek_Error_Rate 0x002e 252 252 051 Old_age Always - 0 8 Seek_Time_Performance 0x0024 252 252 015 Old_age Offline - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 3858 10 Spin_Retry_Count 0x0032 252 252 051 Old_age Always - 0 11 Calibration_Retry_Count 0x0032 100 100 000 Old_age Always - 4 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 20 191 G-Sense_Error_Rate 0x0022 100 100 000 Old_age Always - 2 192 Power-Off_Retract_Count 0x0022 252 252 000 Old_age Always - 0 194 Temperature_Celsius 0x0002 064 056 000 Old_age Always - 34 (Lifetime Min/Max 25/44) 195 Hardware_ECC_Recovered 0x003a 100 100 000 Old_age Always - 0 196 Reallocated_Event_Count 0x0032 252 252 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 252 252 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 252 252 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0036 200 200 000 Old_age Always - 0 200 Multi_Zone_Error_Rate 0x002a 100 100 000 Old_age Always - 0 223 Load_Retry_Count 0x0032 100 100 000 Old_age Always - 4 225 Load_Cycle_Count 0x0032 001 001 000 Old_age Always - 3678853 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 1553 - SMART Selective Self-Test Log Data Structure Revision Number (0) should be 1 SMART Selective self-test log data structure revision number 0 Warning: ATA Specification requires selective self-test log data structure revision number = 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Completed [00% left] (0-65535) 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.